A ruptured pipe or broken sprinkler left undetected can result in substantial damage. Plants and ground cover can be flooded, and slopes can be eroded. The Flow-Clik™ can help identify a break before any damage can occur. The Flow-Clik can be programmed at a specified level of flow; once that level is exceeded, the electrical circuit is broken and the valves are shut off. The amount of water loss in the event of high external leakage is substantially reduced.
Reduced costs for rupture-related repairs
Unanticipated budget allocations kept to a minimum
Weather-proof interface panel provides system status
“Overflow watchdog” provides constant update for any system
Compatible with all commercial and residential piping systems
Large flow range provides complete flexibility
Customized calibration for precise system control
Every irrigation system is set individually with a single push button
Multi-color LED provides system status
Displays if power is applied and whether flow is acceptable
MODELS
FCT Sensor Bodies:
FCT 100 (4.8″ H x 2.3″ W x 4.5″ L) Sch. 40
FCT 150 (5.4″ H x 2.3″ W x 4.6″ L) Sch. 40
FCT 158 (5.4″ H x 2.3″ W x 5.1″ L) Sch. 80
FCT 200 (5.9″ H x 2.7″ W x 4.7″ L) Sch. 40
FCT 208 (6.0″ H x 2.9″ W x 5.4″ L) Sch. 80
FCT 300 (7.0″ H x 4.0″ W x 6.2″ L) Sch. 40
FCT 308 (7.0″ H x 4.2″ W x 6.4″ L) Sch. 80
FCT 400 (6.5″ H x 5″ W x 6.5″ L) Sch. 40
Interface Panel (Flow-Clik Only):
(4.5″ H x 5.5″ W x 1.5″ D) Not required for Flow-Clik IMMS
OPERATING SPECIFICATIONS
• Temperature: 0-150 degrees F
• Pressures: up to 200 PSI
• Humidity: up to 100%
FLOW-CLIK INTERFACE PANEL
36″ leads provided for easy wiring to controller
(2 wires to controller 24VAC terminals and 2 wires to sensor and terminals)
ELECTRICAL SPECIFICATIONS
• Current draw: @24VAC .025 Amps
• Switching current: 2.0 Amps
• Maximum distance between interface panel and sensor = 1000 ft.
(18 gauge minimum wire size) 2 wires required for Flow-Clik Sensor,
4 wires required for Flow-Clik IMMS Sensor to IMMS Interface
FLOW-CLIK ADDITIONAL FEATURES
• Programmable start up delay (0 to 300 Seconds)
• Programmable interrupt period (2 to 60 Minutes)
• System status indicator light
• One button system calibration to highest flow zone
SPECIFICATION GUIDE | |
EXAMPLE: FLOW-CLIK – 150 | |
MODEL HFS =Real time flow meter for ACC controllers FLOW-CLIK = Standard Version for all 24VAC Controllers (includes sensor and interface panel) FLOW-CLIK IMMS = Version for use with IMMS™ Central Control (includes sensor only – interface panel not required for IMMS™) | FEATURES 100 = 1″ Schedule 40 Sensor Body 150 = 1 1/2″ Schedule 40 Sensor Body 158 = 1 1/2″ Schedule 80 Sensor Body 200 = 2″ Schedule 40 Sensor Body 208 = 2″ Schedule 80 Sensor Body 300 = 3″ Schedule 40 Sensor Body 308 = 3″ Schedule 80 Sensor Body 400 = 4″ Schedule 40 Sensor Body |